Female Vaginal swabs only.
Specimen: Vaginal Swab
Collection Device: Aerobic Swab (Teal)
Specimen Storage: Swabs may be stored at room temperature for 24 hours or at 2-8˚C for 36 hours until testing
Color Immunochromatographic Capillary Flow Technology
The OSOM® Trichomonas Rapid Test uses color immunochromatographic, capillary flow, "dipstick" technology. The test procedure requires the solubilization of Trichomonas proteins from a vaginal swab by mixing the swab in Sample Buffer. The OSCOM® Trichomonas Rapid Test Stick is then placed in the sample mixture and the mixture migrates along the membrane surface. If Trichomonas is present in the sample, it will form a complex with the primary anti-Trichomonas antibody conjugated to colored particles (blue). The complex will then be bound by a second anti- Trichomonas antibody coated on the nitrocellulose membrane.
Negative
Monday through Sunday
Available STAT
87808
Rejection Criteria
Note 1. Specimen source is required.
Note 2. Male urine samples may be tested for Trichomonas by Michigan Medicine (MLabs) Laboratory, Test code MTVAGU (Trichomonas vaginalis, Misc sites, by Nucleic Acid Amplification).